iRMC S2/S3
409
IPMI OEM Commands supported by the iRMC S2/S3
F5 B3 - Get Error LED
This command returns information on the status of the server’s Global Error
LED (red) and CSS LED (yellow). The Global Error LED indicates the most
serious error status of the components. The CSS LED indicates, whether the
customer himself can rpair the fault.
Request Data
-
B8
NetFnlLUN: OEM/Group
-
F5
Cmd : Command Group BMC
1:3
80 28 00
IANA-Enterprise-Number FTS, LS byte first
4
B3
Command Specifier
Response Data
-
BC
-
F5
1
Completion Code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS byte first
5
State of Error LED:
0 : CSS off / GEL off
1 : CSS off / GEL on
2 : CSS off / GEL blink
3 : CSS on / GEL off
4 : CSS on / GEL on
5 : CSS on / GEL blink
6 : CSS blink / GEL off
7 : CSS blink / GEL on
8 : CSS blink / GEL blink