![Fujitsu Remote Management User Manual Download Page 247](http://html.mh-extra.com/html/fujitsu/remote-management/remote-management_user-manual_121380247.webp)
iRMC S2/S3
247
Network Settings - Configure the LAN parameters
Refresh every ... seconds
Length (in seconds) of the interval for automatically refreshing the
iRMC S2/S3 web interface.
I
If you enter a value for the refresh interval which is less than the
Session Timeout
(see
page 246
), your session will not automatically
be closed when the time specified in
Session Timeout
has elapsed
in the event of inactivity.
Ports for text-based access
Telnet Port
Telnet port of the iRMC S2/S3
Default port number: 3172
Configurable: yes
Enabled by default: no
Communication direction: inbound and outbound
Session Drop Time
Period of inactivity (in seconds) after which a Telnet connection is
automatically cleared.
SSH Port
SSH (Secure Shell) port of the iRMC S2/S3
Default port number: 22
Configurable: yes
Enabled by default: yes
Communication direction: inbound and outbound
Telnet enabled
If you enable the
Telnet Enabled
option, users can establish a connection
to the iRMC S2/S3 on the Telnet port specified in the entry field.
Summary of Contents for Remote Management
Page 36: ...36 iRMC S2 S3 Notational conventions ...
Page 40: ......
Page 110: ......
Page 134: ...134 iRMC S2 S3 Providing remote storage via a Remote Storage server ...
Page 320: ...320 iRMC S2 S3 Operating iRMC S2 S3 via Telnet SSH Remote Manager ...
Page 346: ...346 iRMC S2 S3 Command Line Protocol CLP Table 18 Hierarchy of the CLP commands ...