![Fujitsu Remote Management User Manual Download Page 205](http://html.mh-extra.com/html/fujitsu/remote-management/remote-management_user-manual_121380205.webp)
iRMC S2/S3
205
Power Consumption
Warning Threshold
Threshold as a percentage of the maximum power consumption
specified under
Power Limit
. When the threshold is reached, the action
defined under
Action Reaching Power Limit
is performed.
Power Limit Grace Period
Period (in minutes) for which the system waits after the threshold has
been reached until the action is performed.
Action Reaching Power Limit
Action to be performed after the threshold has been reached and the
grace period has expired.
Continue
No action is performed.
Graceful Power Off (Shutdown)
Shut down the system "gracefully" and power it down.
I
This option is only supported if ServerView agents are
installed and signed onto the iRMC S2/S3 as “Connected”.
Immediate Power Off
The server is immediately powered down irrespective of the status
of the operating system.
Enable Dynamic Power Control
The power limit is controlled dynamically. If this option is enabled, the
iRMC S2/S3 controls the power consumption of the server system by
reducing the CPU’s power consumption as soon as the
Warning Threshold
is reached.
Summary of Contents for Remote Management
Page 36: ...36 iRMC S2 S3 Notational conventions ...
Page 40: ......
Page 110: ......
Page 134: ...134 iRMC S2 S3 Providing remote storage via a Remote Storage server ...
Page 320: ...320 iRMC S2 S3 Operating iRMC S2 S3 via Telnet SSH Remote Manager ...
Page 346: ...346 iRMC S2 S3 Command Line Protocol CLP Table 18 Hierarchy of the CLP commands ...