iRMC S2/S3
213
Sensors - Check status of the sensors
Fan Test - Test fans
The
Fan Test
group allows you to specify a time at which the fan test is started
automatically or to start the fan test explicitly.
I
Instead of the formerly used full speed testing, most new systems now
provide a modified fan test feature which performs the fan test with a
speed near to the currently required speed. In this case, the fan test is no
longer acoustically noticeable.
Fan Check Time
Enter the time at which the fan test is to be started automatically.
Disable Fan Test
Select this option to disable fan testing.
Ê
Click
Apply
to activate your settings.
Ê
Click
Start Fan Test
to start the fan test explicitly.
System Fans - Specify server behavior in the event that a fan fails
The
System Fans
group provides you with information on the status of the fans.
You can use the options or buttons to select individual fans or all the fans and
specify whether the server should be shut down after a specified number of
seconds if this fan fails.
Select all
Selects all fans.
Deselect all
All selections are cancelled.
Ê
Select the fans for which you wish to define the behavior in the event of a
fault.