400
iRMC
S2/S3
IPMI OEM Commands supported by the iRMC S2/S3
C0 1A - Set Video Display On/Off
This command allows you to switch the local console on or off.
12.1.2.6 BIOS-specific commands
F1 09 - Get BIOS POST State
This command provides information whether BIOS is in POST.
Request Data
-
C0
NetFnlLUN: OEM
-
1A
Cmd : Command Group Fan Test
1
00 = Set Video Display On
01 = Set Video display Off
Response Data
-
C4
-
1A
1
Completion Code
Request Data
-
B8
NetFnlLUN: OEM/Group
-
F1
Cmd : Command Group BIOS
1:3
80 28 00
IANA-Enterprise-Number FTS, LS Byte first
4
09
Command Specifier
Response Data
-
BC
-
F1
1
Completion Code
2:4
80 28 00
IANA-Enterprise-Number FTS, LS Byte first
5
[7:1] - reserved
[0] - BIOS POST State : 0 = BIOS is not in POST
1 = BIOS is in POST
Summary of Contents for Remote Management