260
Chapter 9 Operation and Maintenance
CPU fan speed has exceeded the warning
threshold
CPU fan error.
Check whether there are any obstacles interfering with the
rotation of the CPU fan. If the message still appears, the CPU
fan or baseboard must be replaced. Contact an office listed in
the "Contact Information" of "Start Guide".
CPU fan speed has exceeded the critical
threshold
System fan speed has exceeded warning
threshold
System fan error.
Check whether there are any obstacles interfering with the
rotation of the system fan. If the message still appears, the
system fan or baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide".
System fan speed has exceeded critical
threshold
Power supply fan speed has exceeded warning
threshold
PSU fan error.
Check whether there are any obstacles interfering with the
rotation of the PSU fan. If the message still appears, the PSU
fan or baseboard must be replaced. Contact an office listed in
the "Contact Information" of "Start Guide".
Power supply fan speed has exceeded critical
threshold
System board voltage has exceeded the critical
threshold
Power voltage error. Turn off the server and unplug the power
cable from the outlet. Then, reconnect the power cable and turn
on the server. If the message still appears, the baseboard must
be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
System Event Log utilization has exceeded the
warning threshold. Please save the System
Event Log to a different media and clear it
afterwards.
Cannot write in the event log any more. Store the event log on
another medium and delete the event log as necessary.
Warning!: The array is degraded. Press [Ctrl]
[A] to continue after insert Floppy Disk.
The hard disk failure was detected when the system starts. The
hard disk may be broken down. Check the status of the hard
disk using "OnBoard RAID Utility" disk that comes with this
server without starting the system. For information on how to
check and deal, refer to "
table: List of POST Errors
Message
Description
Summary of Contents for primergy TX150
Page 112: ...112 Chapter 3 OS Installation Using ServerStart ...
Page 140: ...140 Chapter 4 Manual OS Installation ...
Page 174: ...174 Chapter 5 Operations after OS Installation ...
Page 182: ...182 Chapter 6 High Reliability Tools ...
Page 214: ...214 Chapter 7 Installing Internal Options ...
Page 248: ...248 Chapter 8 Configuring Hardware and Utilities ...
Page 300: ...300 D Recycling ...
Page 304: ...304 ...