244
Chapter 8 Configuring Hardware and Utilities
■
Device Properties Submenu
Select [Device Properties] in the [Adapter Properties] window and press the [Enter] key to display the
submenu.
■
RAID Properties Submenu
Select [RAID Properties] in the [Adapter Properties] window and press the [Enter] key to display the
submenu.
table: Items on the Device Properties Submenu
Item
Setting
Description
Restore Defaults
Reads default values for the controller.
MT/Sec
160 (Unchangeable)
Sets the maximum transfer rate.
MB/Sec
Displays the maximum transfer rate.
Data Width
16 (Unchangeable)
Specifies the maximum data transfer width.
Scan ID
Yes (Unchangeable)
Sets whether or not to scan this device at startup.
Scan LUNs > 0
Yes (Unchangeable)
Sets whether or not to scan LUN=1 and subsequent
LUNs at startup.
Disconnect
On (Unchangeable)
Sets whether or not to permit disconnection during
command execution.
SCSI Timeout
10
Specifies the timeout period during command
execution.
Queue Tags
On (Unchangeable)
Sets whether or not to support tagged command
queues.
table: Items on the RAID Properties Submenu
Item
Setting
Description
Array Disk?
• Yes
• No (Initial value)
Sets whether or not to configure an array. Set to
[Yes] to configure an array system (RAID 1) using
onboard SCSI controller.
Hot Spare
• Yes
• No (Initial value)
Sets whether or not to configure a hot spare.
Delete Array
Deletes the RAID configuration when the array system is configured. You can
select this only when array system is configured.
Add/Delete Hot Spare
The server does not support this setting.
Summary of Contents for primergy TX150
Page 112: ...112 Chapter 3 OS Installation Using ServerStart ...
Page 140: ...140 Chapter 4 Manual OS Installation ...
Page 174: ...174 Chapter 5 Operations after OS Installation ...
Page 182: ...182 Chapter 6 High Reliability Tools ...
Page 214: ...214 Chapter 7 Installing Internal Options ...
Page 248: ...248 Chapter 8 Configuring Hardware and Utilities ...
Page 300: ...300 D Recycling ...
Page 304: ...304 ...