Econel 50
Service Supplement
23
Replacement Routines
Replacing the Power Supply Unit
Figure 12: Mounting the front bezel
Ê
Attach the bezel at the slide-in unit (1) until the locking tongues engage (2).
Ê
Insert the slide-in unit into the housing.
Ê
Reconnect the cables.
Ê
Close the server (for a detailed description see the Options Guide) and
reconnect the power plug.
4.5
Replacing the Power Supply Unit
Ê
Remove the left side cover as described in section “General Purposes” on
page 13.
Ê
Remove the system fan (for a detailed description see the Options Guide).
Ê
Remove the cross-beam as described in section “Removing/Mounting the
Cross-beam” on page 16.
Ê
Disconnect all power supply cables from the system board and from the
drives (see cabling in the appendix).
Ê
Swing the power supply unit out from the housing as described in section
“Fold out the Power Supply Unit” on page 14.
1
2
2