36
Service Supplement
Econel
50
Replacing the System Board
Replacement Routines
Ê
Insert the system board into the housing by holding it at a slight angle and
sliding the connectors into the connector panel.
V
CAUTION!
Always take the system board with both hands! See figure 22 on
page 31.
Never lift the system board one-sided or at the heat sink, because
the solder connections between the socket and the board come
under tension and increase the risk of damage and malfunction!
Don’t damage the EMI springs to comply with applicable EMC regula-
tions and satisfy cooling requirements and fire protection measures.
Figure 28: Adjusting the system board
Ê
Carefully place the system board into the housing. Make sure there are no
cables jammed under the system board.
Ê
Adjust the system board. If necessary adjust the position of the system
board with a gentle twisting motion.
I
When the system board is in the right position the centering rings engage
in the holes indicated.
Ê
Fasten the system board with the 10 screws.