Econel 50
Service Supplement
31
Replacement Routines
Replacing the System Board
V
CAUTION!
Always take the system board with both hands! Figure 22 shows the
handling by the example of a sample board.
Never lift the system board one-sided or at the heat sink,
because the solder connections between the socket and the
board come under tension and increase the risk of damage and
malfunction!
Don’t damage the EMI springs to comply with applicable EMC regula-
tions and satisfy cooling requirements and fire protection measures.
Figure 22: Handling of the board (example)
Ê
Place the removed system board on an antistatic surface.
Ê
Unscrew the four screws of the heat sink and remove it (for description see
the Technical Manual for the system board D1859).