Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
558
Copyright 2011 FUJITSU LIMITED
P2X0-1090-02ENZ0
REMCS Defaults
The REMCS recommended pattern of event notification is as follows. For the notification meth-
ods indicated with "*", ON/OFF setting has been changed from the system default.
Level
Event
Notification method
Host Sense
Key Code
Qualifier
SNMP
Trap
syslog
REMCS
Error
Parts Error
Selected
Selected
Selected
Cleared
Selected
(fixed)
Disk Error
Any Time
Cleared *
Selected
Selected
Cleared
Selected
(fixed)
when
HS<0
Cleared
Selected
*
Selected
*
Cleared
–
Temperature Error
Selected
Selected
Selected
Cleared
Selected
(fixed)
End of battery life
Selected
Selected
Selected
Cleared
Selected
(fixed)
Rebuild/Copyback w/
redundant
Cleared *
–
–
–
–
Rebuild/
Copyback
w/o
redundant
Any Time
Selected
–
–
–
–
when
HS<0
Selected *
–
–
–
–
Complete rebuild
Selected
Selected
Selected
Cleared
Selected
(fixed)
Bad data
Selected
Selected
Selected
Cleared
Selected
(fixed)
Pinned data
Selected
Selected
Selected
Cleared
Selected
(fixed)
Not ready
Selected
Selected
Selected
Cleared
Selected
(fixed)
Remote Path Error
Selected
Selected
Selected
Cleared
Selected
REC Buffer Halt (Path
Error)
–
Selected
Selected
Cleared
Selected
REC Buffer Halt
(Overload)
–
Selected
Selected
Cleared
Selected
REC Buffer Halt (Other
Error)
–
Selected
Selected
Cleared
Selected
Thin Provisioning Pool
Rate
–
Selected
Selected
Cleared
–