Chapter 11 System Management
11.2 Functions in the Action Area for System
ETERNUS Web GUI User’s Guide
487
Copyright 2011 FUJITSU LIMITED
P2X0-1090-02ENZ0
11.2.3.13 Setup Syslog
This function sets up external servers (Syslog server) for sending logs of events that are
detected by the ETERNUS DX Disk storage system.
Up to two syslog servers can be registered.
The following events are sent as syslogs:
•
All the notification target events that are configured using the procedure in
Event Notification" (page 550)
•
Logins and logouts from GUI and CLI
The procedure to set up the Syslog is as follows:
Procedure
1
Click [Setup Syslog] in [Action].
2
Specify the parameters, and click the [Set] button.
•
Send Log
Select from "on (RFC3164)", "on (RFC5424)", or "off" for Syslog sending.
"RFC3164" and "RFC5424" are log sending formats (protocols).
•
Domain Name/IP Address
Enter the domain name or the IP address of the Syslog server.
The following input conditions apply:
-
For "IP Address": Numeric characters for all the text boxes (0 - 255)
-
For "Domain Name": Alphanumeric characters between 1 and 63
•
Port No.
Enter the port number used to send a Syslog.
The following input conditions apply:
-
Numeric characters
-
1 - 65535
•
LAN Port
Select the LAN port from "MNT" or "RMT" that is to be used to send a Syslog.
•
Select whether to send ("on") or not send ("off") Syslogs for each
ETERNUS DX Disk storage system.
•
Confirm that the Syslog has been successfully sent to the Syslog server
by logging in and out from GUI or CLI and performing a transmission
test to the Syslog server.
•
Even if a communication error occurs between the ETERNUS DX Disk
storage system and the Syslog server, the Syslog is not sent again.
•
"11.2.7.1 Setup Event Notification" (page 550)
for
specifying events to be notified as a Syslog.
•
Syslogs are sent to both Syslog servers at the same time.
•
The parameter settings for Syslog remain even when the "Send Log"
setting is changed to "off".