Chapter 9 Connectivity Management
9.1 Connectivity Status
ETERNUS Web GUI User’s Guide
263
Copyright 2011 FUJITSU LIMITED
P2X0-1090-02ENZ0
The following items are displayed in the Main area:
•
Host Port Group
•
Host
The "Host Group Name" or "Host Name" for which the host affinity setting is configured is
displayed. By clicking this item, the [Host Affinity] screen is displayed.
If "All" is displayed for the "Host Group Name" or "Host Name" field, all of the hosts can
access the ETERNUS DX Disk storage system.
•
CA Port Group
The port group names for which the host affinity setting is configured are displayed.
If there is a port, which has not been registered in a port group, a "-" (hyphen) is displayed in
the "CA Port Group" field of the corresponding port.
•
CA Port
A "-" (hyphen) is displayed in the "CA Port" field of the port group for which the host affinity
setting is configured.
If there is a port that has not been registered in a port group, the location information of the
corresponding port is displayed.
-
CM#x CA#y Port#z (x: CM number, y: CA number, z: Port number)
•
LUN Group
The LUN group name, of which host affinity setting has been configured, is displayed.
•
Host Response
The host response, of which host affinity setting has been configured, is displayed.
If a host group has been configured, the host response, which had been assigned when the
host group was registered, is displayed.
If a host group is not configured ("All" is displayed in the "Host Port Group" field), the host
response that is assigned to "All" is selected using the procedure in
is displayed.
If a host group is not configured (a "-" (hyphen) is displayed in the "Host Port Group" field), the
host response, which has been assigned to the host or the CA port, is displayed.
-
Windows EMPD (*1)
-
Linux EMPD (*1)
-
Solaris EMPD (*1)
-
Solaris MPxIO
-
HP-UX
-
AIX EMPD (*1)
-
AIX VxVM
-
AIX Single Path
-
VS850/SVC
-
Host responses created in the ETERNUS DX Disk storage system
-
Others
*1:
EMPD: ETERNUS Multipath Driver