Parameter Data Formats
4-56
C141-C010
4.2.4.3 Total posted read errors (Page 03, Code 0002)
Bit
Byte
7
6
5
4
3
2
1
0
4
5
(MSB)
X'0002' (Parameter code)
(Total Posted Errors)
(LSB)
DU
DS
TSD
ETC
TMC
LBIN
LP
6
0
0
0
0
0
0
0
0
7
X'04' (Parameter Length)
8
(MSB)
9
10
Counter Value
11
(LSB)
The Counter Value indicates the count of all posted errors to the interface during read operations. The
value includes the count of all posted verify errors to the interface (page X'05', Parameter code X'0002').
Implementation:
If a read error is posted, it will force a save of all error log pages information.
4.2.4.4 Total posted recoverable read errors (Page 03, Code 0003)
Bit
Byte
7
6
5
4
3
2
1
0
4
5
(MSB)
X'0003' (Parameter code)
(Total Posted Recoverable Errors)
(LSB)
DU
DS
TSD
ETC
TMC
LBIN
LP
6
0
0
0
0
0
0
0
0
7
X'04' (Parameter Length)
8
(MSB)
9
10
Counter Value
11
(LSB)
The Counter Value indicates the count of all posted recovered (01/xx/xx) errors to the interface during
read operations. The value includes the count of all posted recovered verify errors (page X'05',
Parameter code X'0003').
Summary of Contents for 80
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 62: ...This page is intentionally left blank ...
Page 284: ...Sense Data Error Recovery Methods This page is intentionally left blank ...
Page 296: ...This page is intentionally left blank ...
Page 298: ...This page is intentionally left blank ...
Page 308: ...This page is intentionally left blank ...
Page 309: ......
Page 310: ......