4.2 Log Parameters
C141-C010
4-67
The values stored in the General usage parameter bytes represent data sent to the device server in a
previous LOG SELECT command. If a previous LOG SELECT command has not occurred, the data is
zero.
4.2.10 Self-test result page (X'10')
Bit
Byte
7
6
5
4
3
2
1
0
0
0
0
0
1
0
0
0
0
1
X‘00’ (Reserved)
2
Page Length (MSB)
3
Page Length (LSB)
All of the following parameters have this header.
Page Length will be defined based on the value of Parameter Pointer. (CDB 5-6)
4.2.10.1 Self-test result parameter data (Page 10, Code 0001-0014)
Bit
Byte
7
6
5
4
3
2
1
0
4
5
(MSB)
X'0001'-X'0014' (Parameter code)
(Self-Test Result Parameter)
(LSB)
DU
DS
TSD
ETC
TMC
LBIN
LP
6
0
0
0
0
0
0
1
1
7
X'10' (Parameter Length)
8
Self-Test Code
0
Self-Test Result Value
9
Self-Test Segment Number
10
11
(MSB)
Time Stamp
(LSB)
12
(MSB)
Address of First Failure
19
(LSB)
20
0
0
0
0
Sense Key
21
Additional Sense Code
22
Additional Sense Code Qualifier
23
X'xx' (Vendor-specific)
~
~
~
~
~
~
Summary of Contents for 80
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 62: ...This page is intentionally left blank ...
Page 284: ...Sense Data Error Recovery Methods This page is intentionally left blank ...
Page 296: ...This page is intentionally left blank ...
Page 298: ...This page is intentionally left blank ...
Page 308: ...This page is intentionally left blank ...
Page 309: ......
Page 310: ......