4.2 Log Parameters
C141-C010
4-65
The Accounting date specified by parameter code 0002h is a parameter that may be savable using a LOG
SELECT command to indicate when the device was placed in service. If the parameter is not yet set or
is not settable, the default value placed in the parameter field shall be 6 ASCII blank characters (20h).
The field shall not be checked for validity by the device server.
4.2.8.3 Specified cycle count over device lifetime (Page 0E, Code 0003)
Bit
Byte
7 6 5 4 3 2 1 0
4
5
(MSB)
X'0003' (Parameter code)
(Specified Cycle Count Over Device Lifetime)
(LSB)
DU DS TSD
ETC
TMC
LBIN LP
6
0 1 0 0 0 0 1 1
7
X'04' (Parameter Length)
8 (MSB)
9
10
Specified Cycle Count Over Device Lifetime (4-byte binary number)
11 (LSB)
The Specified cycle count over device lifetime is a parameter provided by the device sever. The
specified cycle count over device lifetime parameter shall not be savable by the application client using
the LOG SELECT command. The parameter value is a 4-byte binary number. The value indicates how
operation or reliability outside the limits specified by the manufacture of the device.
4.2.8.4 Start-stop cycle counter (Page 0E, Code 0004)
Bit
Byte
7 6 5 4 3 2 1 0
4
5
(MSB)
X'0004' (Parameter code)
(Accumulated Start-Stop Cycles)
(LSB)
DU DS TSD
ETC
TMC
LBIN LP
6
0 1 0 0 0 0 1 1
7
X'04' (Parameter Length)
8 (MSB)
9
10
Accumulated Start-Stop Cycles (4-byte binary number)
11 (LSB)
Summary of Contents for 80
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 62: ...This page is intentionally left blank ...
Page 284: ...Sense Data Error Recovery Methods This page is intentionally left blank ...
Page 296: ...This page is intentionally left blank ...
Page 298: ...This page is intentionally left blank ...
Page 308: ...This page is intentionally left blank ...
Page 309: ......
Page 310: ......