3.1 Control/Sense Commands
C141-C010
3-41
3.1.9
REZERO UNIT (01)
Bit
Byte
7 6 5 4 3 2 1 0
0 X‘01’
1
LUN
0 0 0 0 0
2
0 0 0 0 0 0 0 0
3
0 0 0 0 0 0 0 0
4
0 0 0 0 0 0 0 0
5
0 0 0 0 0 0 0
Link
This command moves the read/write heads of the disk drive to the initial position. A data block with the
logical block address of zero exists at the initial position (cylinder 0 / track 0). Initialization of the disk
drive's positioning control system and automatic adjustment are also performed by this command.
3.1.10 START/STOP UNIT (1B)
Bit
Byte
7 6 5 4 3 2 1 0
0 X‘1B’
1
LUN
0 0 0 0
Immed
2
0 0 0 0 0 0 0 0
3
0 0 0 0 0 0 0 0
4
0 0 0 0 0 0
LoEj
Start
5
0 0 0 0 0 0 0
Link
This command controls starting and stopping of the disk drive's spindle motor. Control of the spindle
motor is performed through the "Start" bit in bit 0 of the CDB byte 4.
The spindle motor can be stopped if this command is issued with the "Start" bit as "0." On the other
hand, the spindle motor can be started by specifying "1" in the "Start" bit.
Bit 1 (LoEj (Load/Eject) of byte 4 of the CDB is the exclusive bit which controls devices with
replaceable recording media, and it has no meaning for the IDD. The IDD disregards the value specified
in this bit and controls starting and stopping of the spindle motor in accordance with the "Start" bit only.
Summary of Contents for 80
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 62: ...This page is intentionally left blank ...
Page 284: ...Sense Data Error Recovery Methods This page is intentionally left blank ...
Page 296: ...This page is intentionally left blank ...
Page 298: ...This page is intentionally left blank ...
Page 308: ...This page is intentionally left blank ...
Page 309: ......
Page 310: ......