107
Error Message List
Error
Message
Reason Solution
Bad fiber
end-face.
Check the condition of the fiber cleaver. If the blade is
worn, rotate the blade to a new position.
Large
Cleave
Angle
[Cleave Limit] is
set too low.
Increase the [Cleave Limit] to an adequate limit.
[Core Angle
Limit] is set too
low.
The splicer measures the core angle only when using
other splice modes. Increase the [Core Angle Limit]
to an adequate limit. (1.0 degree is standard)
Dust or dirt is on
the V-groove or
the clamp chip.
Clean the V-groove and clamp chip, and set the fibers
again. If the error occurs again, strip, clean and cleave
the fibers.
Large
Fiber
Angle
Bad fiber
end-face.
Check the condition of fiber cleaver. If the blade is
worn, rotate the blade to a new position.
Cleave
Shape NG
Bad fiber
end-face.
Check the condition of fiber cleaver. If the blade is
worn, rotate the blade to a new position.
Arc
Discharge
Delayed
Arc Discharge is
delayed
• Assure the electrodes are in proper position.
• Execute the [Stabilize Electrode] function.
• Replace the electrodes.
Inadequate arc
power
Calibrate the arc power with the [Arc Calibration]
function.
Prefuse power or
time is set too high
If using the Other mode, adjust or initialize [Prefuse
Power] or [Prefuse Time] settings. For normal splice
mode, the prefuse is fixed and cannot be adjusted.
Thin Fiber
Insufficient
[Overlap] setting
Fat Fiber
Too much
[Overlap] setting
• If using the Other mode, adjust or initialize [Overlap]
setting. For normal splice mode, the overlap is fixed
and cannot be adjusted.
• Execute [Motor Calibration] function in the
maintenance menu to calibrate the stuff amount.
Too
Tapering
Fiber
Too much fiber
taper.
If using the taper splice function, the error message
may appear meaning the fiber is tapered too much.
Bad fiber
end-face.
Check the condition of fiber cleaver. When the blade
is worn, rotate the blade.
Bubble
Prefuse power or
time is set too low
If using the Other mode, adjust or initialize [Prefuse
Power] or [Prefuse Time] settings. For normal splice
mode, the prefuse is fixed and cannot be adjusted.
Bad fiber
end-face.
Check the condition of the fiber cleaver. If the blade is
worn, rotate the blade to a new position.
Large Dust
Burn
[Cleaning Arc]
time is too short or
“OFF.”
Dust still present after cleaning fiber or cleaning arc.
Clean fiber thoroughly or Increase [Cleaning Arc
Time]