106
Error Message List
Error
Message
Reason Solution
Dust or dirt is on the
fiber surface.
Completely prepare the fiber again (strip,
clean and cleave).
Select the suitable splice mode. Pressing the
The left and right fiber
types are different.
SET key cancels the error and continues the
splice operation.
Cannot detect
fiber in
AUTO mode
Splicing non-standard
fibers.
The AUTO mode can identify standard SM,
DS, MM and NZDS fiber only.
Strong
Arc Power
Unable to calibrate due
to strong arc.
Weak
Arc Power
Unable to calibrate due
to weak arc.
Too Left Arc
Unable to calibrate due
to poor arc field position
(too far left).
Too Right
Arc
Unable to calibrate due
to poor arc field position
(too far right).
Replace the electrodes by using the [Electrode
Replace] function. If this does not eliminate
the problem, consult your distributor.
The fiber stuff amount is
insufficient.
Execute the [Motor Calibration] function. If
using other splice modes, check the [Overlap]
setting in the splice mode.
Fiber
Separation
The pre-fuse power or
pre-fuse time is set too
high.
Check the [Prefuse Power] and [Prefuse Time]
settings in the splice mode.
L-Bad Fiber
Position
R-Bad Fiber
Position
The fiber is not set
correctly at the bottom
of the V-groove.
Press RESET key, and re-position the fiber
again to seat it correctly at the bottom of the
V-groove.
No Arc
Discharge
Arc Discharge did not
occur.
• Assure the electrodes are in proper position.
• Replace the electrodes.