Setting Menu
3-1.
Change of Operating Direction
The splicer is shipped from the factory with settings for the “Monitor Front” operation
style. This can be changed to “Monitor Rear” operation style. The sheath clamp direction
can also be changed for the selected style. When [Monitor Position] is changed, the
direction of the four arrow keys is reversed.
Changing monitor position
(1)Change monitor angle. The Monitor image direction changes automatically when
[Auto] is selected. See previous page for detail.
Monitor Front Monitor Rear
(2) Change direction of sheath clamps.
1. Loosen and remove screws with a driver, and remove sheath clamp.
2. Remove the other sheath clamp by same way.
3. Attach the opposite sheath clamps and tightens screws.
Loosen the screw
Remove the sheath clamp
Attach the sheath clamp (opposite)
Tighten the screw