37
Basic Operation
6-2.
Fiber holder System
(1) Set the fiber onto the fiber holder with the fiber protruding 30 to 40mm from the end
of the fiber holder and then close the fiber holder lid.
(2) Strip the sheath by tool from the fiber.
Notes
(3) Clean the bare part of the fiber with alcohol-impregnated gauze or lint-free tissue.
30mm~40mm
• Close the lid of a fiber holder while pressing down with a finger on the coating
(refer to figure below).
• Select a suitable fiber holder based on the fiber coating diameter.
• If fiber coating has some memory curl, place fiber so that the curve of memory is
turned upwards.
Pressing down with a finger
Pressing down with a finger strongly
Pressing down with a finger strongly
1~3mm