Confidential: FUJIFILM Service Center Use Only
X-Pro1 Service Manual
3-33
3-16. [F1]:Battery Voltage Adjustment
[Adjustment environment and precautions]
• If you have not been using the battery jig up until the immediately preceding adjustment, briefly pause the adjustment
software (press "X" in the adjustment item select screen) and then turn the camera off.
Then set the battery jig as the power supply (set the designated voltage) and then restart the adjustment software.
• Measure the voltage at the battery jig clip position.
• Ensure that the voltage provided by the regulated power supply does not suddenly decrease during adjustment. If the voltage
drops significantly below the designated voltage, the camera turns off, communication between the adjustment software and
the camera is interrupted and an error occurs.
[Required items]
Camera fixing jig
If there are no problems with the adjustment environment, a tripod or X-Y
stage can be used.
Regulated power supply
Digital Voltmeter
NP-W126 Battery jig
ZJ01936-100
<Settings for Battery Voltage Adjustment>
NP-W126 Battery Jig
Summary of Contents for X-Pro1
Page 4: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 4 MEMO...
Page 6: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 6 MEMO...
Page 56: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 1 50 MEMO...
Page 100: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 3 40 MEMO...
Page 124: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 5 10 MEMO...
Page 128: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 6 4 MEMO...
Page 130: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 7 2 MEMO...
Page 132: ...Confidential FUJIFILM Service Center Use Only X Pro1 Service Manual 8 2...