– 22 –
3
Chapter
Overview of Operation Parameters (Ch1)
Operation parameters handle all operation controls.
The operation menu includes the following items.
Note 1: Displays when the seventh digit of the model code is H, K, F, 2 or E, or the eleventh digit is D.
Note 2: Displays when the ninth digit of the model code is not 0, or the eleventh digit is C.
Note 3: The range of the parameters in the shaded area indicates the industrial values.
Note 4: When changing the SV value with the front panel key, do not change the "
Svn
" parameter with communication. The
changed SV value may not be stored correctly.
Display
Parameter name
Function
Setting range
Initial
value
Remarks
Page
"
Man
" (Man)
Switches to manual
mode
Switches between auto/manual
modes
oFF (off)/on (manual)
oFF
23
"
STbY
" (STbY)
Switches between
RUN and standby
Switches the operation mode
between run and standby
oFF (off)/on (standby)
oFF
24
"
rEM
" (rEM)
Switches to remote
SV operation
Switches between local and
remote SV operation
LoCL (Local)/
rEM (Remote)
LoCL
(Note 1)
24
"
PrG
" (PrG)
Ramp/Soak
Operation
command
Switches between ramp/soak
operation states
oFF (stop)
rUn (run)
hLd (hold)
oFF
Displays End
when finished,
and GS during
guaranteed soak.
25
"
AT
" (AT)
Auto-tuning
running command
Runs auto-tuning.
oFF (stop/finish)
on (normal type)
Lo (low PV type)
oFF
25
"
LACH
" (LACH)
Cancel command of
the DO output latch
Cancels the DO output latch state
oFF/ rST
(latch reset)
oFF
(Note 2)
26
"
Svn
" (Svn)
Selecting SV
number during
SV selection
Chooses the SV No. used for
control
Sv0 (Local SV)
Sv1 (SV=SV1)
Sv2 (SV=SV2)
Sv3 (SV=SV3)
Sv4 (SV=SV4)
Sv5 (SV=SV5)
Sv6 (SV=SV6)
Sv7 (SV=SV7)
di (select SV based on di)
Sv0
(Note 4)
26
"
PLn1
" (PLn1)
Currently selected
PID No.
Chooses the PID group No. used
for control
Pid0 (PID Ch)
Pid1 (PID group No. 1)
Pid2 (PID group No. 2)
Pid3 (PID group No. 3)
Pid4 (PID group No. 4)
Pid5 (PID group No. 5)
Pid6 (PID group No. 6)
Pid7 (PID group No. 7)
di (select Pid group No.
based on di)
Pid0
27
"
AL1
"
"
AL1l
"
"
AL1h
"
"
AL5
"
"
AL5l
"
"
AL5h
"
AL1 Setting
AL1L Setting
AL1h Setting
AL5 Setting
AL5L Setting
AL5h Setting
Sets the alarm set value.
0 to 100% FS
(Absolute Alarm)
-100 to 100% FS
(Deviation Alarm)
10%
(Note 3)
27
"
LoC
" (LoC)
Key lock
Sets the key lock to prevent
operation errors
0 (no lock)
1 (all lock)
2 (all but SV locked)
0
28
…
…
Summary of Contents for PXG4
Page 1: ...c...
Page 10: ...9 1 Chapter Chapter 1 Part Names and Functions Part Names and Functions 10...
Page 21: ...20 MEMO 2 Chapter...
Page 43: ...42 MEMO 4 Chapter...
Page 53: ...52 MEMO 5 Chapter...
Page 71: ...70 MEMO 7 Chapter...
Page 89: ...88 MEMO 8 Chapter...
Page 106: ...105 9 Chapter Behavior when control is lost Limit Cycle PV SV Time tuning MV control lost 100...
Page 119: ...118 MEMO 10 Chapter...
Page 125: ...124 MEMO 11 Chapter...
Page 131: ...130 MEMO 12 Chapter...
Page 141: ...140 MEMO 14 Chapter...
Page 151: ...150 MEMO 15 Chapter...
Page 152: ...151 16 Chapter Chapter 16 Troubleshooting Troubleshooting 152...
Page 157: ...156 MEMO 17 Chapter...