Handling Precautions
Processing chemicals should be handled in accordance with the precautions indicated on the boxes and labels of the
respective chemicals.
●
Always wear protective gloves and safety goggles when handling chemicals with the above
indications. This is recommended even for chemicals without these indications. For greater
protection, the use of a protective mask and apron is also recommended.
●
Wash hands thoroughly after handling processing chemicals or solutions.
●
Any spilled chemicals should be wiped up immediately.
●
Use caution when mixing chemicals as certain mixtures may produce toxic gases.
●
If you get any chemical on your skin or in your eyes, immediately flush the affected part with
a great amount of water.
●
If you swallow any chemical or get any in your eyes, seek medical attention immediately and
show the physician the information printed on the box or label of the chemical(s) involved.
●
In some countries, chemicals carrying a poison label are required by law to be stored under
lock and key. You are responsible for ascertaining and complying with the regulations that
apply in your country concerning the handling of poisonous substances.
●
Store chemicals in a safe place out of reach of children.
●
Waste solutions should be disposed of in accordance with the ordinances governing the
handling of industrial waste products in your locale. The P1-R chemical in the CP-48S
replenisher cartridge and the Component A of the P1 start-up chemical fall into the category
of industrial waste. Should you have any questions concerning these chemicals, consult
your service representative.
Special note should be taken regarding the following properties of the CP-48S chemicals.
●
The P1-R chemical of the Replenisher Cartridge PC and Component A of the P1 Start-up
Chemical
These components contain P-phenylenediamine and may thus cause skin and eye irritation
if improperly handled. They may be injurious to the health if swallowed.
●
The P2-RA Chemical of the Replenisher Cartridge PC and Component A of the P2 Start-up
Chemical
These components cause oxidation in metals. They may produce harmful ammonia gas if
mixed with a chlorine-based bleach (hypochlorite) or an alkaline substance (P1-R or N1-RA).
●
The P2-RB Chemical of the Replenisher Cartridge PC and Component B of the P2 Start-up
Chemical
These components may produce harmful ammonia gas if mixed with a chlorine-based
bleach (hypochlorite) or an alkaline substance (P1-R or N1-RA). They may also produce
harmful sulfur trioxide gas when mixed with an acid.
●
FSC100 (Fuji Super Conditioner)
This component contains dichloroisocyanurate and may thus produce harmful chlorine gas if
mixed with an acid. It could be injurious to the health if swallowed.
Safety Goggles
Protective Gloves
1.6
Processing Chemical (CP-48S) Handling
Summary of Contents for FRONTIER 390
Page 11: ...9 1 OPERATIONAL SAFETY AND USE CONDITIONS 9 GD1550 1 ...
Page 12: ...10 10 GD1559 1 3 2 Caution Label Locations on Printer Paper Processor ...
Page 13: ...11 1 OPERATIONAL SAFETY AND USE CONDITIONS 11 GD1560 ...
Page 19: ...17 1 OPERATIONAL SAFETY AND USE CONDITIONS 17 GD1550 2 ...
Page 165: ...169 10 LIST OF CONSUMABLES 10 1 Scanner 170 10 2 Printer Processor 171 ...
Page 168: ...173 11 INDEX 5 1 Index 174 5 2 Index of Basic Operating Instructions 176 ...