y
Click [Print].
• After about 5 minutes, a condition setup print is
fed out to the large-size tray.
u
After the condition setup print has come
out, press the [Dens Measure] button.
i
Adjust the guide of the densitometer
according to the width of the condition
setup print.
■
Densitometer Operation Panel
When an error occurs, press the orange
[RESET] switch.
Densitometer
Guide
EZ634
Indicator Lamp
Ready
Measuring
Error
POWER (Green)
ON
ON
ON
READY (Green)
ON
Blink
OFF
ERROR (Red)
OFF
OFF
ON