136
Fronius IG
Plus 50
Input data
MPP voltage range
230 - 500 V DC
Max. input voltage
600 V DC
(at 1000 W/m²/ -10 °C (14 °F) in an open circuit)
Max. input current
18.3 A DC
Output data
Nominal output power (P
nom
)
4 kW
Max. output power
4 kW
Nominal mains voltage
1 ~ NPE 220 / 230 V, +10 / -15 %
1)
Nominal output current (one phase)
18.2 / 17.4 A AC
Nominal frequency
50 - 60 Hz
1)
Harmonic distortion
< 3.5 %
Power factor cos phi
1
Max. permitted mains impedance Zmax at PCC
2)
261 mOhm
General data
Maximum efficiency
96 %
Europ. max. efficiency
95.1 %
Power consumption at night
< 1 W
Cooling
Controlled forced ventilation
Protection class
IP 44
Dimensions l x w x h
244 x 434 x 631 mm (9.6 x 17.1 x 24.8 in)
Weight
25 kg (55.1 lb)
Permissible ambient temperature
-20 °C - +50 °C (-4 °F - +122 °F)
(with 95% rel. humidity)
EMC emission class
B
Protective equipment
DC insulation measurement
Warning when R
ISO
< 500 kOHM
DC overvoltage protection
integrated
Protection against reversed polarity
integrated
Manifestation of DC overload
Operating point shift
Summary of Contents for Fronius IG Plus 100
Page 2: ......
Page 4: ...ud_fr_st_et_01382 012008...
Page 14: ...6...
Page 15: ...7 General Information...
Page 16: ...8...
Page 20: ...12...
Page 21: ...13 Installation and Startup...
Page 22: ...14...
Page 71: ...63 Closing Fronius IG Plus Closing Froni us IG Plus 1 1 4 2 7 3 5 6...
Page 77: ...69 Operation...
Page 78: ...70...
Page 118: ...110...
Page 119: ...111 Troubleshooting and Maintenance...
Page 120: ...112...
Page 141: ...133 Appendix...
Page 142: ...134...
Page 152: ...144...
Page 155: ......