92
1. Select the ‘STAND
BY
’ menu
option
2. Press the ‘Enter’ key
The standby mode will activate
(manual deactivation of the grid
feed).
The Operating Status LED
flashes orange.
The display switches between
...
‘STAND
BY
’ and
‘ENTER’
3. Press the ‘Esc’ to exit the
‘STAND
BY
’ menu option
1. Open the setup menu
2. Select the desired menu option
3. Press the ‘Enter’ key
4. Use the ‘Up’ and ‘Down’ keys to change the value of the menu option
5. Press the ‘Enter’ key - the changed values will be saved in the menu
option
6. Press the ‘Esc’ key to exit the menu option
Restoring the grid feed:
Activate ‘STAND
BY
’ - manual deactivation of the grid feed:
1. Select the ‘STAND
BY
’ menu option
2. Press the ‘Enter’ key
The Fronius IG Plus will switch to the Startup phase.
After a successful startup, the Operating Status LED will be green.
The current power feed will be displayed.
Setting and Displaying Menu Options
General Menu
Option Set-
tings
Setting the
‘STAND
BY
’
Menu Option
Summary of Contents for Fronius IG Plus 100