ALARMS
E2 : FILM FINISHED OR BROKEN
Problem suggestion
Possible solution
- Tension on the film to high
- Check tension by regulating the parameters during the
movements bottom (1) – upwards (2) – top (3)
– downwards (4) (
Fig. 1
)
- If the film becomes to narrow , film tension is too High.
(Max 10% reduction from 500mm)
- Check the position of the analogue sensor and
functioning of the dancer roller.
- Pre-Stretch on the film to high
- Check the pre-stretch by regulating the parameters
during the movements bottom (1) – upwards (2) –
top (3)– downwards (4) (
Fig. 1
)
- Change the quality of the stretchfilm
Fig. 1
- The dancer roller is not moving or difficult to
move backwards and forewards
-
Clean the dancer roller (1) (
Fig.1
)
-
Remove dirt or film residuals
-
Grease the dancer roller shaft (2) (
Fig 2 & 3
)
-
Release the top or bottom spring (3) (
Fig 2 & 3
)
Fig. 1
Fig. 2
Fig. 3
Should the problem persist, contact the Customer After-Sales Service of MANUFACTURER