INSTALLATION INSTRUCTION
ATTENTION!
All mentioned activities may only be executed under supervision of qualified personnel from the
manufacturer or his representatives!
Refer to layout in
SAFETY DEVICES
for mentioned position numbers.
General guideline
Always check in advance that the minimum conditions for machine placing and operation are
observed, in particular: ambient conditions (suitable floor), temperature, humidity, lighting and
suitability of the designated area.
Installation in rooms subject to the risks of flooding, explosion and fire is strictly forbidden.
The area necessary for installation of the wrapping machine is the area according to the dimensions on
the layout plus enough space for installing and working on the machine.
Installation must be executed by qualified personnel, directly coordinated by the authorized Technical
Service, fully observing the instructions that follow, in addition to current safety and health laws.
As a precaution, always check for any damage caused during transport and handling work.
If necessary, contact the Manufacturer directly.
Temperature
For safety make sure the machine is operating at ambient temperature in the range +5°C to +30°C.
lf other values are measured, contact the Authorized Technical Service with utmost urgency.
Work areas
It is strictly forbidden to locate and/or use the machine if the ambient conditions are liable to cause
risks of explosion or inflammability.
Ensure that the following are not present: dust concentration, gas, dangerous fumes and particles,
electrostatic fields, excessive electro-magnetic flow, or anything else that might be harmful to persons
so exposed or to the efficient running of the machine.
In any event, observe the current safety and health laws.
The machine should be placed on a flat, rigid, vibration-free concrete floor
Never access the high parts of the machine improperly.
Energy sources
The client must provide a cable suited for the required supply voltage up to the control cabinet, of which
the diameter of the conductors can manage the total of the required power as mentioned in chapter
TECHNICAL DATA
The wrapping machine should preferably be connected to the customer's supply voltage wall socket with
a connecting cable with a standard CEE-plug, being fused with a 16A-fuse (slow).
For the correct plug check chapter
TECHNICAL DATA
A main switch preceding the plug has to be provided by the customer, if necessary.
The mains supply must satisfy the applicable standards, such as permitted voltage fluctuations, ripple-
generation, reduction of high harmonics, etc.