Installers and service technicians
Initial startup
Page 60
B0190806
s
7
Untrained operators may enter incorrect settings!
Incorrectly set parameters at “Installer” and “Service” level can
cause serious problems with boiler functioning!
7.4.3
Setting system type
ENTER
ENTER
Boiler types and parameters
FHG …
FHG … do not select, position the arrow on one of the other types.
P2 – 10 …X
←
←
←
←
Lambda probe
available
N
←
←
←
←
Y, if a Lambda probe is available.
P2 – 15 …
Boilerlaunch in av
N
←
←
←
←
See page 35, “10.10 Boiler release”
P2 – 20 …
Boiler off when
no heat required
N
←
←
←
←
Automatic operation of the system in transitional or
winter operation. The boiler is started when required by a
heating circuit or by the DHW tank
P2 – 25 …
Supply bin
N
←
←
←
←
Y, if the system is manually fed with a supply bin
Screw discharge
N
←
←
←
←
Y, if chamber discharge is carried out by direct screw
discharge.
Suction screw
discharge
N
←
←
←
←
Y, if chamber discharge is carried out by direct screw
discharge.
Manual univ.
suction system
N
←
←
←
←
Y, if chamber discharge is carried out by manual universal
suction system.
Automatic univ.
suction system
N
←
←
←
←
Y, if chamber discharge is carried out by automatic
universal suction system.
Clean
Y
←
←
←
←
Daily cleaning of combustion bowl
MANUAL ANAL. OUT
SYSTEM SELECTION
Boiler types ...
System ...
SET
ERROR DISPLAY
repeatedly