Lambdatronic P 3100 control system
Menus and parameters
Page 28
B0190806
s
4
4.4.1
Settings menu
In the “Settings” operating menu the most important parameters and
values for the system can be changed:
Setting boiler temperature
Boiler temp.
...
Boiler temp. should be
80°C
The boiler temperature is regulated to this
temperature
Set storage tank temperatures
Storage tank
...
Storage temp. heat
circ. launch
30°C
Only for systems with storage tanks
Minimum temperature for releasing the
heating circuit. (Sensor 1)
Store up. min. temp.
60°C
Upper store temperature, below which the
boiler is started in transitional operation.
Set DHW tank temperatures
DHW tank
...
Set DHW temp
55°C
When the specified temperature is reached
in the DHW tank, the DHW tank loading
pump switches off.
Desired DHW tank 2
temperature
60°C
When the specified temperature is reached
in DHW tank 2, DHW tank loading pump 2
switches off.
Reload when the DHW
tank is below
45°C
Reloading of the DHW tank is authorised
when the DHW tank temperature is below
this level.
Reload when the DHW
tank is below
45°C
Reloading of the second DHW boiler is
authorised when the DHW boiler
temperature is below this level.
Start of 1st loading
05:00
Start of authorisation for 1st DHW tank
loading session
End of 1st loading
08:00
End of authorisation for 1st DHW tank
loading session
Start of 2nd loading
15:00
Start of authorisation for 2nd DHW tank
loading session
End of 2nd loading
18:00
End of authorisation for 2nd DHW tank
loading session
Only heat once a day
N
“Y” prevents heating up several times in
one day
Legionella heating 65°
Y
The DHW tank is heated to at least 65°C
once a week
Legionella heating day
Mo
Day of the week for Legionella heating.