9.
Unscrew screw connection of the mains connection cable and
position it vertically. Screw in the elbow connector (A or D). Since
there is very limited space for a screwdriver, the mains cable must
be moved if necessary. Turn the elbow connector (A or D) until it is
positioned vertically. Afterwards, press the removed connecting
element back onto the screw connection.
10.
Then, the cable of the funnel safety switch (B) is inserted into
elbow connector (A or D) and the housing.
11.
One cable of the safety switch is connected at the top left, and the
other is connected at the bottom right (where the blue cable
bridge (X) was previously attached).
12.
Push the cable conduit of the funnel into the elbow connector.
13.
Afterwards, close the main switch.
Accessories