96
PB
TROUBLESHOOTING
Overcurrent Protection E5
Start
Is the supply voltage unstable with big fluctuation?
Is the supply voltage too low with overload?
Is the indoor / outdoor heat exchanger too dirty,
or are the air inlet and outlet blocked?
current higher than the value of the overcurrent
Measure the current of live wire
on the main board with a clamp ampere meter. Is the
protection?
Is the fan motor running abnormally; is the fan speed too
low or does it fail to run?
Is there blockage inside the system?
(Filth blockage, ice plug, greasy blockage, the Y-valve hasn’ t
been opened completely)
no
no
no
no
yes
Is the compressor running
abnormally? Is there abnormal sound or oil leakage; is
the temperature of the shell too high, etc.?
no
no
panel
Replace the control
End
yes
Malfunction is eliminated.
no
Normal fluctuation is within 10% of the rated voltage on the
nameplate
yes
Adjust the supply voltage to maintain it within normal range
Malfunction is eliminated.
no
yes
Malfunction is eliminated.
Clean the indoor and outdoor heat exchangers and remove
the blockage of air inlet and outlet
no
yes
Check the motor and reinstall the motor to have the fan run
normally
Malfunction is eliminated.
no
Replace the controller
no
Malfunction is eliminated.
no
Flush the heat exchangers with high pressure nitrogen
yes
no
Malfunction is eliminated.
Replace the compressor
yes
Malfunction is eliminated.
no
yes
yes
yes
yes
yes
yes
yes
Summary of Contents for MRM09Y1J
Page 8: ...8 INTRODUCTION MWM09Y1J MWM12Y1J Figure 101 Indoor Units MWM18Y3J MWM24Y3J MWM36Y3J...
Page 37: ...37 OPERATION 18 24kSequenceofOperation...
Page 38: ...38 OPERATION 18 24k Sequence of Operation O o 0 C L A B C D 1 1 4...
Page 39: ...39 OPERATION 18 24k Sequence of Operation...
Page 40: ...40 OPERATION 18 24k Sequence of Operation...
Page 41: ...41 OPERATION 18 24k Sequence of Operation...
Page 47: ...47 INSTALLATION...
Page 48: ...48 INSTALLATION Installation Tools...
Page 95: ...95 TROUBLESHOOTING Malfunction of IDU Fan Motor U8 Service Manual No Start End...
Page 116: ...116 FIgure 901 PARTS CATALOG Indoor Unit MWM09Y1J MWM12Y1J MWM09Y1J MWM12Y1J...
Page 118: ...118 FIgure 902 PARTS CATALOG Indoor Unit MWM18Y3J MWM24Y3J...
Page 123: ...123 FIgure 904 PARTS CATALOG Outdoor Unit MRM09Y1J MRM12Y1J MRM09Y1J MRM12Y1J...
Page 126: ...126 PARTS CATALOG Outdoor Unit MRM18Y3J FIgure 905...
Page 128: ...128 PARTS CATALOG Outdoor Unit MRM24Y3J FIgure 906...