Figure 215
9K Cooling Capacity Charts
DB
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
14
5.63
4.59
0.25
6.11
5.03
0.26
6.56
5.32
0.27
7.01
5.68
0.28
7.52
6.00
0.29
7.68
6.24
0.30
7.94
6.76
0.30
17
5.72
4.64
0.26
6.41
5.17
0.27
6.75
5.46
0.28
7.16
5.83
0.29
7.80
6.24
0.30
8.12
6.50
0.31
8.13
6.95
0.31
23
6.30
5.04
0.28
6.77
5.42
0.30
7.25
5.80
0.30
7.71
6.17
0.31
8.41
6.64
0.32
8.64
6.93
0.33
9.23
7.30
0.34
59
7.63
6.10
0.35
8.20
6.56
0.38
8.77
7.01
0.39
9.43
7.47
0.40
9.60
7.68
0.41
10.48
8.38
0.43
11.05
8.84
0.42
70
9.78
7.40
0.50
10.39
7.90
0.52
11.24
8.39
0.54
11.48
8.72
0.55
11.80
8.73
0.57
12.67
9.63
0.60
13.53
10.28
0.61
75
9.46
7.19
0.53
10.10
7.68
0.55
10.74
8.16
0.56
11.18
8.50
0.58
11.50
8.51
0.60
12.31
9.35
0.62
13.20
10.03
0.64
80
9.06
6.61
0.57
9.69
7.07
0.59
10.23
7.53
0.60
10.78
7.87
0.62
11.20
8.06
0.64
11.93
8.71
0.66
12.77
9.32
0.69
85
8.18
5.92
0.60
8.65
6.32
0.62
9.32
6.74
0.64
9.69
7.07
0.66
10.07
7.25
0.68
10.79
7.88
0.71
11.52
8.41
0.74
90
7.12
5.60
0.79
8.70
6.01
0.82
9.30
6.42
0.84
9.80
6.76
0.86
10.20
7.04
0.89
10.98
7.58
0.93
11.77
8.05
0.95
95
7.94
5.48
0.85
8.54
5.89
0.88
9.13
6.30
0.90
9.73
6.71
0.93
10.11
6.90 0.96
10.92
7.53
1.00
11.51
7.94
1.03
100
7.54
5.13
0.88
8.01
5.53
0.92
8.59
5.92
0.95
9.26
6.32
0.98
9.50
6.56
1.01
10.31
7.11
1.05
10.77
7.51
1.08
105
7.19
4.96
0.93
7.85
5.35
0.96
8.23
5.74
0.99
8.89
6.14
1.02
9.30
6.42
1.05
10.03
6.92
1.09
10.59
7.31
1.13
110
6.89
4.82
1.05
7.55
5.21
1.07
8.12
5.61
1.10
8.76
6.00
1.14
9.10
6.28
1.18
9.82
6.78
1.22
10.35
7.17
1.26
115
5.05
3.82
0.79
5.45
4.14
0.81
5.78
4.46
0.84
6.29
4.78
0.86
6.60
4.95
0.89
7.14
5.43
0.93
7.56
5.74
0.95
118
4.26
3.51
0.65
4.77
3.81
0.68
5.08
4.07
0.70
5.47
4.37
0.71
5.72
4.58
0.74
6.21
4.96
0.77
6.55
5.24
0.79
77 / 64
80 / 67
MM09YJ Indoor Air Temperature :DB / WB
86 / 72
90 / 75
Outdoor
Air Temp.
64 / 53
68 / 57
72 / 61
DB
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
14
6.52
4.95
0.33
7.12
5.42
0.33
7.53
5.72
0.37
8.04
6.11
0.38
8.50
6.46
0.39
8.84
6.72
0.41
9.58
7.28
0.42
17
6.54
4.97
0.38
7.31
5.54
0.39
7.70
5.85
0.38
8.22
6.25
0.40
8.80
6.69
0.41
9.17
6.97
0.43
9.80
7.45
0.44
23
7.06
5.37
0.48
7.65
5.77
0.50
8.12
6.17
0.51
8.64
6.57
0.53
9.30
7.07
0.54
9.70
7.38
0.56
10.23
7.77
0.58
59
8.12
6.17
0.60
8.67
6.63
0.65
9.32
7.09
0.65
9.93
7.55
0.67
10.21
7.76
0.69
11.15
8.47
0.72
11.75
8.93
0.74
70
11.10
7.66
0.74
11.58
8.17
0.78
12.59
8.68
0.80
13.08
9.03
0.82
13.45
9.28
0.85
14.44
9.96
0.89
15.42
10.64
0.91
75
10.67
7.36
0.81
11.23
7.86
0.86
12.11
8.35
0.87
12.60
8.69
0.89
12.96
8.94
0.92
13.86
9.56
0.95
14.88
10.27
0.99
80
10.22
7.05
0.88
10.93
7.54
0.91
11.63
8.03
0.93
12.16
8.39
0.96
12.63
8.71
0.99
13.46
9.28
1.03
14.40
9.94
1.06
85
9.66
6.66
0.89
10.35
7.14
0.92
11.03
7.61
0.95
11.58
7.99
0.98
12.04
8.31
1.01
12.90
8.90
1.05
13.78
9.51
1.08
90
10.38
7.06
1.05
11.10
7.58
1.08
11.90
8.10
1.11
12.55
8.54
1.14
13.06
8.88
1.18
14.07
9.57
1.23
14.93
10.15
1.26
95
10.04
6.83
10.90
10.79
7.34
1.11
11.54
7.85
1.14
12.30
8.36
1.18
12.64
8.60 1.22
13.80
9.38
1.27
14.55
9.89
1.30
100
9.29
6.32
1.15
10.23
6.80
1.19
10.72
7.29
1.21
11.44
7.78
1.25
11.86
8.06
1.29
12.87
8.75
1.34
13.58
9.24
1.38
105
8.83
6.00
1.21
9.52
6.48
1.26
10.22
6.95
1.29
10.92
7.42
1.33
11.42
7.77
1.36
12.31
8.37
1.42
13.01
8.85
1.46
110
8.48
5.76
1.26
9.25
6.22
1.27
9.85
6.70
1.31
10.54
7.16
1.35
11.03
7.50
1.40
11.91
8.10
1.45
12.60
8.57
1.49
115
6.65
5.06
0.98
7.22
5.49
1.03
7.78
5.91
1.05
8.33
6.33
1.09
8.74
6.64
1.12
9.45
7.18
1.17
10.00
7.60
1.20
118
5.80
4.64
0.86
6.31
5.04
0.91
6.72
5.38
0.93
7.22
5.78
0.96
7.56
6.05
0.99
8.19
6.55
1.02
8.65
6.92
1.06
64 / 53
68 / 57
72 / 61
77 / 64
80 / 67
Outdoor
Air Temp.
MM12YJ Indoor Air Temperature :DB / WB
90 / 75
86 / 72
Figure 214
12K Cooling Capacity Charts
Symbol
DB : Dry Bulb Temperature [ °F}
WB :Wet Bulb Temperature [ °F}
TC: Total Capacity
[kBtu/h]
SHC: Sensible Heating Capacity
[kBtu/h]
PI: Power Input
[kW]
(Comp + indoor fan motor +outdoor fan motor)
Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2. Indicates reference data. When operating at this temperature, these values can be different by operation.
3. Direct interpolation is permissible. Do not extrapolate.
4. Capacities are based on the following conditions:
Interconnecting Piping length 7.5m (24.6 ft) - Level difference of 0 FT
Indoor Air Temperature: 80°F (26.7°C) DB / 67°F (19.4°C) WB
Outdoor Air Temperature: 95°F (35.0°C) DB 75°F (23.9°C) WB
Summary of Contents for MRM09Y1J
Page 8: ...8 INTRODUCTION MWM09Y1J MWM12Y1J Figure 101 Indoor Units MWM18Y3J MWM24Y3J MWM36Y3J...
Page 37: ...37 OPERATION 18 24kSequenceofOperation...
Page 38: ...38 OPERATION 18 24k Sequence of Operation O o 0 C L A B C D 1 1 4...
Page 39: ...39 OPERATION 18 24k Sequence of Operation...
Page 40: ...40 OPERATION 18 24k Sequence of Operation...
Page 41: ...41 OPERATION 18 24k Sequence of Operation...
Page 47: ...47 INSTALLATION...
Page 48: ...48 INSTALLATION Installation Tools...
Page 95: ...95 TROUBLESHOOTING Malfunction of IDU Fan Motor U8 Service Manual No Start End...
Page 116: ...116 FIgure 901 PARTS CATALOG Indoor Unit MWM09Y1J MWM12Y1J MWM09Y1J MWM12Y1J...
Page 118: ...118 FIgure 902 PARTS CATALOG Indoor Unit MWM18Y3J MWM24Y3J...
Page 123: ...123 FIgure 904 PARTS CATALOG Outdoor Unit MRM09Y1J MRM12Y1J MRM09Y1J MRM12Y1J...
Page 126: ...126 PARTS CATALOG Outdoor Unit MRM18Y3J FIgure 905...
Page 128: ...128 PARTS CATALOG Outdoor Unit MRM24Y3J FIgure 906...