84
PB
TROUBLESHOOTING
Diagnostic Codes
No. Malfunction
Name
Display Method of Indoor Unit
Display Method of Outdoor Unit
A/C status
Possible Causes
Dual-8
Code
Display
Indicator Display (During blinking,
ON 0.5s and OFF 0.5s)
Indicator has 3 kinds of display
status and during blinking, ON
0.5s and OFF 0.5s
Power
Indicator
Cool
Indica
-
tor
Heating
Indicator
Yellow
Indicator
Red Indi-
cator
Green
Indicator
9
Limit/
decrease
frequency
due to high
temperature
EU
OFF 3s
and blink
6 times
OFF 3s
and blink
6 times
All loads operate normally,
while
operation frequency for
compressor is decreased
Discharging after the com
-
plete unit is de-energized
for 20mins, check whether
the thermal grease on IPM
Module of outdoor control
the radiator is inserted
tightly.
If its no use, please replace
control panel AP1.
10
Malfunction
protection of
jumper cap
C5
OFF 3s
and blink
15 times
Wireless remote receiver
and button are effective, but
can not dispose the related
command
1.No jumper cap insert on
mainboard.
2.Incorrect insert of jumper
cap.
3.Jumper cap damaged.
4.Abnormal detecting
circuit of mainboard.
11
Gathering
Refrigerant
F0
OFF 3s
and blink
once
OFF 3s
and blink
once
OFF 1s
and blink
17 times
When the outdoor unit
receive signal of Gathering
refrigerant ,the system
will be forced to run under
cooling mode for gathering
refrigerant
Nominal cooling mode
12
Indoor
ambient
temperature
sensor is
open/ short
circuited
F2
OFF 3s
and blink
once
During cooling and drying
operation, indoor unit
operates while other loads
will stop; during heating
operation, the complete unit
will stop operation.
1.Loosening or bad contact
of indoor ambient temp.
sensor and mainboard
terminal.
2.Components in main
-
board fell down leads short
circuit.
3.Indoor ambient temp.
sensor damaged.(check
with sensor resistance
value chart)
4.Mainboard damaged.
Summary of Contents for MRM09Y1J
Page 8: ...8 INTRODUCTION MWM09Y1J MWM12Y1J Figure 101 Indoor Units MWM18Y3J MWM24Y3J MWM36Y3J...
Page 37: ...37 OPERATION 18 24kSequenceofOperation...
Page 38: ...38 OPERATION 18 24k Sequence of Operation O o 0 C L A B C D 1 1 4...
Page 39: ...39 OPERATION 18 24k Sequence of Operation...
Page 40: ...40 OPERATION 18 24k Sequence of Operation...
Page 41: ...41 OPERATION 18 24k Sequence of Operation...
Page 47: ...47 INSTALLATION...
Page 48: ...48 INSTALLATION Installation Tools...
Page 95: ...95 TROUBLESHOOTING Malfunction of IDU Fan Motor U8 Service Manual No Start End...
Page 116: ...116 FIgure 901 PARTS CATALOG Indoor Unit MWM09Y1J MWM12Y1J MWM09Y1J MWM12Y1J...
Page 118: ...118 FIgure 902 PARTS CATALOG Indoor Unit MWM18Y3J MWM24Y3J...
Page 123: ...123 FIgure 904 PARTS CATALOG Outdoor Unit MRM09Y1J MRM12Y1J MRM09Y1J MRM12Y1J...
Page 126: ...126 PARTS CATALOG Outdoor Unit MRM18Y3J FIgure 905...
Page 128: ...128 PARTS CATALOG Outdoor Unit MRM24Y3J FIgure 906...