5
MULTIPLE USERS
The system allows for up to 6 Users and a Master
User to be configured. This allows the system Event
Log to maintain a record of which users have armed
and disarmed the system. Each user will have a
different User Access Code. In addition a 4 second
voice recorder facility enables the user’s name to be
recorded for use with the Latch Key facility.
Only the Master User has access to the programming
functions and is able to configure the system.
Note:
Any Remote Control Units on the system will be
recorded as User 6.
SYSTEM ARMING
The system has a ‘Full Arm’ and 2 ‘Part-Arm’ modes.
ARM will ‘Arm’ all zones while the ‘Part-Arm’ modes will
only arm the zones that are enabled for the particular
Part-Arm mode.
For example:
The system could be configured so that during night
time, ‘Part-Arm 1’ would arm
only zones protecting the
lower floor and outbuildings
leaving the upper floor
free for movement without
triggering the alarm.
During the day while the property is occupied ‘Part-Arm
2’ could arm only the zones protecting the outbuildings.
However, when the property is left un-occupied, the
‘Full Arm’ mode will arm all zones to protect the entire
property, (i.e. upper and lower floors and outbuildings).
ENTRY/EXIT DELAY
When the system is armed with the Exit-Delay enabled,
no signal from any detector on an active zone will
be able to trigger an alarm until the Exit-Delay has
expired. This enables the system to be armed from
within the property and allows time for the user to
exit the property without triggering an alarm. If the
Exit-Delay is disabled then detectors on active zones
will immediately be able to trigger an alarm once the
system is armed.
The system Exit-Delay may be configured for between
10 to 250 seconds or disabled completely.
If a detector on a zone with its Entry-Delay enabled is
triggered, then an alarm will not sound until the Entry-
Delay period has expired. This allows time for the user
to re-enter the property and disarm the system before
an alarm occurs. Generally only the zones on the main
entry route to the property will be configured with an
Entry-Delay. The remaining zones would be configured
with their Entry-Delay disabled allowing them to
immediately initiate an alarm the instant a detector on
the zone is triggered.
The Entry-Delay for each zone may be configured for
between 10 to 250 seconds or disabled completely.
Note:
To conserve power and maximise battery life
the PIR Detector will only detect movement if there
has been no movement detected within the previous
2 minutes. Consequently the PIR Detector will not
become active until the protected area has been free
from movement for more than 2 minutes.
ZONES
The system incorporates 6 wirefree alarm zones for
the connection of the system detectors that are used to
independently monitor different areas of the property.
In addition to standard intruder protection, each zone
may also be configured to operate in 1 of 4 other
modes:
- ‘PANIC/PA’ mode provides 24 hour monitoring of any
Personal Attack (PA) switches incorporated into the
system.
- ‘24-hour Intruder’ mode provides 24 hour intruder
protection for areas/zones where continuous monitoring
is required, (e.g. gun lockers).
- ‘Fire’ mode provides 24 hour monitoring of any Fire/
Smoke detectors incorporated into the system.
- ‘Test’ mode allows a zone to be monitored while
the system is armed. If a detector on a test zone is
triggered an entry will be recorded in the Event Log but
an alarm will not occur.
In addition there is the facility to connect 4 hard wired
zones to the Control Panel, each of which is fully
configurable with the same features as the wirefree
zones.
ZONE LOCKOUT
If a detector on an active zone is triggered while
the system is armed an alarm will sound. After the
programmed alarm duration has expired the alarm
will stop and the system will automatically reset.
Subsequent detectors triggered will again trigger an
alarm. If a single zone triggers an alarm more than
INTRODUCTION AND OVERVIEW
Full Arm
����������
����������