31
24 Hour Intruder -
used to provide 24 hour monitoring
of areas requiring continuous security protection even
while the system is Disarmed, (e.g. gun lockers).
Activation of any detector on a security zone will
immediately initiate an Alarm.
Fire -
use to provide 24 hour monitoring of any Fire/
Smoke detectors fitted to the system. Activation of any
detector will immediately initiate an Alarm.
Test -
when the system is armed, any detector on the
zone will generate an entry in the Event Log without
initiating an alarm.
Note:
Personal Attack, 24 hour Intruder and Fire
modes all operate on a 24 hour basis, (i.e. they
are able to initiate an Alarm at any time even if the
system is Disarmed).
Default setting: ‘Intruder’
Scroll through the menu until ‘
3-2 Z01 Type
’ (and the
current setting) is displayed.
To change the setting press .
Scroll through the menu options until the required
setting is displayed.
Press to save and exit, or
Press to exit without saving.
FINAL EXIT SET
This controls whether the zone will trigger the systems
Final Exit Set feature. Triggering a detector on a
“Final Exit Set Zone” during the exit-delay will reset the
remaining exit-delay to 5 seconds.
Default setting: OFF
Scroll through the menu until ‘
3-3 Z01 Final Exit Set
’
(and the current setting) is displayed.
To change the setting press .
Press to enable the zone’s Final Exit Set
facility, or
Press to disable the zone’s Final Exit Set
facility.
CHIME
This controls whether the zone will operate with Chime
Mode.
Default setting: OFF
Scroll through the menu until ‘
3-4 Z01 Chime
’ (and the
current setting) is displayed.
To change the setting press .
Press to enable the zone in Chime Mode, or
Press to disable the zone in Chime Mode.
ENTRY DELAY
Scroll through the menu until ‘
3-5 ENTRY DELAY
’ (and
the current setting) is displayed.
To change the settings press .
On/Off Status
Default setting:
zone 1:
ON
zones 2-10:
OFF
Scroll through the menu until ‘
3-5-1 Status
’ (and
the current setting) is displayed.
To change the settings press .
Press to enable the zones Entry-Delay,
or
Press to disable the zone’s Entry-Delay.
Delay Period
Default setting: 30 seconds
Scroll through the menu until ‘
3-5-2 Delay Time
’
(and the current setting) is displayed.
To change the settings press .
Enter the required delay period (10 to 250
seconds).
Press to save and exit, or
Press to exit without saving.
Press to return to top level Zone Setup.