49
5.
Ensure that detector is mounted the correct way up, (i.e.
with detection window at the bottom).
6.
Ensure that the detector is mounted at the correct height,
(i.e. 2-2.5 metres).
7.
Allow up to 3 minutes for detector to stabilize and
become fully operational. Leave the area for this period.
8.
Ensure detector is within effective radio range of the
Control Panel and is not mounted close to metal objects
which may interfere with Radio transmission.
PIR Movement Detector LED flashes on detection
of movement, (device in normal operation mode).
1.
Ensure that the detector is configured for normal
operation, (i.e. DIP switch 4 of SW3 is OFF).
2.
Low battery - replace battery.
Magnetic Contact Detector not working.
1.
Ensure that Magnet is correctly positioned in relation to
Detector and that the gap between magnet and detector
is less than 10mm.
2.
Ensure batteries are fitted with correct polarity.
3.
Ensure battery holder connections are making good
contact with the batteries and PCB.
4.
Ensure ‘House Code’ is correctly set to the same code as
all other system devices.
5.
Ensure DIP switches 9, 10 and 11 are correctly set,
according to required zone.
6.
If there is no additional wired Magnetic Contact
connected ensure jumper link is fitted.
7.
If an additional wired Magnetic Contact is connected:
a. Ensure jumper link is removed.
b. Check that both contacts are closed.
c. Check that additional contact is correctly wired.
Note:
If an additional contact is used then the doors/
windows protected by both the main wirefree detector
and the additional wired detector must be closed when
either one is opened. If one of the doors/windows is
already open then the opening of the other door/window
will not be detected.
8.
Ensure detector is within effective radio range of Control
Panel and is not mounted close to metal objects which
may interfere with Radio transmission.
Magnetic Contact Detector false alarming
1.
Ensure that Magnet is correctly positioned in relation to
Detector.
2.
Ensure that gap between magnet and detector is less
than 10mm.
3.
Tamper switch below battery cover not depressed - check
battery cover is fitted correctly and that fixing lugs are not
broken.
LED on Magnetic Contact Detector illuminating
when door or window is opened
1.
Low battery - replace batteries.
Voice-Dialler Not Responding to Alarm
1.
Telephone line not connected or faulty - check phone line
with another phone.
2.
Dial Method incorrectly programmed.
3.
Incorrect phone numbers programmed.
4.
Phone numbers disabled in dialling sequence.
5.
Alarm messages not recorded.
Answerphone
not responding or recording
messages.
1.
Telephone line not connected or faulty - check phone line
with another phone.
2.
Dial Method incorrectly programmed.
3.
Answerphone disabled.
4.
No space in message store, 6 messages already
recorded.
Cannot record Voice-Memo message at Control
Panel.
1.
No space in message store, 6 messages already
recorded.
Control Unit Not Contacting Remote Manager
Service on Alarm
1.
Telephone line not connected or faulty - check phone line
with another phone.
2.
Dial Method incorrectly programmed.
3.
Incorrect phone number for Remote Security Manager
Service programmed.
4.
Incorrect system ID number for Remote Security
Manager Service programmed.
5.
Remote Security Manager Service not commissioned or
signed up.
Remote Phone Access and Control facility not
functioning:
1.
Telephone line not connected or faulty - check phone line
with another phone.
2.
Remote Access disabled.
3.
Incorrect User Access Code entered.
Latch Key Not Responding when system Disarmed
1.
Telephone line not connected or faulty - check phone line
with another phone.
2.
Dial Method incorrectly programmed.
3.
Latch Key disabled.
4.
Latch Key set to Selected-Users and not enabled for
User that is Disarming the system.
5.
No Latch Key phone numbers programmed.