20
12.
If for any reason you need to disable the Siren,
remove jumper link P3 on the circuit board. This
will prevent the Siren from sounding during an
alarm condition. However, the Siren will still beep
to acknowledge signals from the Remote Control,
(provided the beep feature has not been disabled).
P3 fitted
Siren enabled
P3 removed
Siren disabled
13.
To enable the Jamming Detect feature in the Solar
Siren fit the jumper link taped to the cover of the Siren
control unit across link pins P1 on the circuit board.
P1 fitted
Jamming Detection enabled
P1 removed
Jamming Detection disabled
14.
Refit the DIP switch cover and replace the 3 cover
fixing screws. Do not over tighten the screw as this
could damage the thread.
POWERING UP THE SIREN
Connect the 9V PP3 power-up battery to the battery
clip.
1.
Connect the rechargeable battery to the charging
leads. Connect the Red lead to the Red (
+
) terminal
and the Black lead the Black (
-
) terminals. Both
indicator LEDs will flash together in a single long flash
to indicate that the unit is operational.
2.
Press the tamper switch, both indicator LEDs
will flash together several times. The LED’s will
then continue to flash alternately every 10 seconds
thereafter to indicate that the Siren is functioning.
3.
Hinge the front cover locating tabs over the top
edge of the back plate and carefully push the base of
the siren cover into place. Secure the Siren cover in
place by refitting the fixing screw in the bottom edge of
the cover. Do not over tighten the screw as this could
damage the thread.
IMPORTANT:
Ensure that the rear tamper switch
is closed when you fit the siren cover to the back-
plate (i.e. listen for the switch to click). If the
switch does not close it will prevent the Siren from
operating correctly. If necessary, remove the siren
cover again and adjust the screw on the back-plate
tamper plunger to ensure the switch closes when
the Siren is secured in position. If fitted remove the
protective film covering the Solar Panel.
Testing the Solar Siren:
4.
Use the and buttons to scroll through
the menu until ‘
ALARM TEST
’ is displayed and press
. .
5.
Scroll through the menu until ‘
WIREFREE SIREN
TEST
’ is displayed and press
.
The solar siren should activate for a period of
approximately 5 seconds.
6.
Press to return to the top level menu of
Test Mode.
IMPORTANT:
The Siren must now be left in position
for at least 24 hours to fully charge the Main Battery
before testing or operating the alarm.