24
RESET FACTORY SETTINGS
1.
Press .
This puts the system into Test Mode.
2.
Undo the Control Panel cover fixing screws and
open the cover.
3.
Remove the DC power jack, then remove and
disconnect one of the back-up batteries.
4.
Set jumper link P1 to the ON position.
5.
Reconnect the power supply jack.
6.
The Control Panel will now re-set itself with all
factory settings.
‘
EEPROM RESET
’ will be displayed while the factory
settings are restored to memory.
Once the memory reset has been completed ‘
DISARM
READY
’ will be displayed.
7.
Reconnect and replace the back-up battery.
8.
Reset jumper link P1 into the OFF position.
9.
Close the Control Panel cover and refit the fixing
screws.
PROGRAMMING
INSTRUCTIONS
With the system in Standby (i.e. with the display
showing “DISARM READY”).
Press
The system is now in Programming Mode
Navigating through the Programming
Mode Menus
(read carefully before you start)
The programmable system parameters are arranged by
group in a series of menus within programming mode.
Each menu (and sub-menu) will contain all
programmable system parameters related to the
particular function.
Note:
Some basic system parameters will be contained
within the system menu because they relate to a
number of different functions.
At each menu level use the and buttons to
scroll through the available options.
Note:
A menu item displayed in full capitals (e.g. ‘FULL
ARM SETUP’) indicates that there is another menu
below that option. An option displayed in lower case
(e.g. ‘5.2 Entry Delay Beep’) indicates that this is a
parameter setting and no menu below, (although there
may be setting options).
Press to:
a.
select the displayed menu, or
b.
change the displayed parameter setting, or
c.
save the changed parameter setting and revert to
the previous level.
Press to:
a.
exit to the previous menu level, or
b.
revert to the previous level without saving a changed
parameter setting.
Note:
After programming all required functions,
press to leave Programming mode and return to
Standby.
OFF
ON
Jumper
Link P1
,
,
Master User Access Code
,
,
User Access Code