FR100L&FR200L For Wire drawing machine
- 17 -
fault occurred
U01.12
Output current when
before-previous fault
occurred
0.0
~
3000.0A
0.0A
⊙
U01.13
Bus voltage when
before-previous fault
occurred
0
~
1200V
0V
⊙
U01.14
Cumulative running time
when before-previous
fault occurred
0
~
65535h
0h
⊙
Group H00: Special Function Code for wire drawing machine
H00.00
Type of wire drawing
machine
0
:
host drive in water tank wire
drawing machine
1
×
1
:
Winding drive in water tank
wire drawing machine
2
:
Unwinding drive
3
:
Straight line wire drawing
machine
H00.01
Balance bar centre point
setting
0.0~100.0%
50.0%
△
H00.02
Balance bar feedback
source
0: AI1
1: AI2
2: Communication given
3: HI pulse input
0
×
H00.03
Proportional gain P
0.0
~
100.0%
40.0%
△
H00.04
Integral time Ti
0.00
~
300.00s
0.00
△
H00.05
PID effect upper limit
PID effect lower limit
~
100.0%
100.0
%
×
H00.06
PID effect lower limit
-100.0%
~
PID PID effect upper
limit
-100.0
%
×
H00.07
Feedforward frequency
given source
0: Digital given (Setting H00.08)
1: AI1
2: AI2
3: Communication given
4: HI pulse input
Windin
g:2
Unwin
ding:0
Straigh
t line:2
×
H00.08
Feedforward frequency
digital given
0.0%~100.0%
100.0
%
△
H00.09
Roll diameter coefficient
K upper limit
0.0%~600.0%
Winding:3
00.0%
Unwindin
g:100.0%
Straight
line:300.0
%
△
H00.10
Roll diameter coefficient
K starting value
0.0%~ feedforward gain limit
Winding:1
00.0%
Unwindin
g:0.0%
Straight
line:200.0
%
△
H00.11
Smooth starting time
0.0~120.0s
Winding
:1.0s
Unwindi
ng:0.0s
Straight
line:0.0s
△
H00.12
Smooth start K increment
per second
0.00~100.00%
0.60%
△
H00.13
Roll diameter coefficient
0.0%~Roll diameter coefficient
2.0%
△