- 18 -
range 1
range 2
H00.14
Roll diameter coefficient
range 2
Roll diameter coefficient range
1~3
10.0%
△
H00.15
Roll diameter coefficient
range 3
Roll diameter coefficient range
2~4
20.0%
△
H00.16
Roll diameter coefficient
range 4
Roll diameter coefficient range
3~5
30.0%
△
H00.17
Roll diameter coefficient
range 5
Roll diameter coefficient range
4~100.0%
35.0%
△
H00.18
Roll diameter coefficient
K increment 1
0.00~100.00%
0.05%
△
H00.19
Roll diameter coefficient
K increment 2
0.00~100.00%
0.08%
△
H00.20
Roll diameter coefficient
K increment 3
0.00~100.00%
0.50%
△
H00.21
Roll diameter coefficient
K increment 4
0.00~100.00%
1.00%
△
H00.22
Roll diameter
coefficient K increment 5
0.00~100.00%
6.00%
△
H00.23
Wire break control mode
Units
:
Wire break determine
mode
0
:
Automatic determine
1
:
External signal
Tens
:
Wire break VFD statue
0
:
Constant running
1
:
Stop after the delay
2
:
Coast to stop
Windin
g:21
Unwin
ding:11
Straigh
t
line:21
×
H00.24
Wire break determine
delay time after starting
0.0~20.0s
5.0s
△
H00.25
Wire break automatic
determine time
0.0~20.0s
1.0s
△
H00.26
Wire break feedback
lower limit value
0.0%~Wire
break
feedback
upper limit value
5.0%
△
H00.27
Wire break feedback
upper limit value
Wire break feedback lower limit
value ~100.0%
95.0%
△
H00.28
Running time after wire
break
0.0~120.0s
10.0s
△
H00.29
Running frequency after
wire break
0.00~60.00Hz
5.00Hz
△
H00.30
Synthesized frequency
output upper limit
Synthesized frequency output
lower limit~100.0%
100.0
%
×
H00.31
Synthesized frequency
output lower limit
-100.0%~Synthesized frequency
output upper limit
Winding
:0.0%
Unwindi
ng:-15.0
%
Straight
line:0.0
%
×
H00.32
Modulator function
0:Positive
1:Negative
Windin
g:0
Unwin
ding:1
Straigh
t line:1
×
3.2 Group HOO Function Cde
H00.00
Type of wire drawing
0
:
host drive in water tank
1
×