FR100L&FR200L For Wire drawing machine
- 11 -
6: Coast to stop
7: Fault reset (RESET)
……
39
:
line break fault
Group F05 Digital Output
F05.00
Y1 output function
0: No output
1
×
F05.01
Y2 output function
1: Drive is running
3
F05.02
Relay 1 output function
2
:
Inverter fault
2
×
3:Frequency-level
detection (FDT1)
4:Frequency-level
detection (FDT2)
……
20
:
Underload alarm
Group F07 Analog and Pulse Output
F07.00
AO1 output function
0: No output
1
×
F07.01
AO2 output function
1: Output frequency
2
×
F07.02
Y2/HO output function
(when used as HO)
2: Command frequency
1
×
3: Output current
4: Output voltage
5: Output power
6: Bus voltage
7
:
+10V
8: keypad potentiometer
9:AI1
10:AI2
11:AI3
12:HI
13: Output torque
Group F08 Parameters of Motor 1
F08.01
Power rating of motor 1
0.10
~
600.00kW
Model
×
F08.02
Rated voltage of motor 1
60
~
660V
defined
×
F08.03
Rated current of motor 1
0.1
~
1500.0A
Model
×
F08.04
Rated frequency of
motor 1
20.00
~
Fmax
defined
×
F08.05
Rated speed of motor 1
1
~
30000
Model
×
F08.06
Wiring mode of motor 1
0
:丫
defined
Model
×
1
:
Δ
F08.07
Rated power factor of motor 1
0.50
~
0.99
defined
×
F08.08
Stator resistance R1 of
async motor 1
0.001
~
65.535Ω
Model
×
F08.09
Rotor resistance R2 of
async motor 1
0.001
~
65.535Ω
defined
×
F08.10
Leakage inductance L1
of async motor 1
0.001
~
65.535mH
Model
×
F08.11
Mutual inductance L2 of
asynchronous motor 1
0.1
~
6553.5mH
defined
×
F08.12
No-load current of
async motor 1
0.1
~
1500.0A
Model
×
F08.13
Field weakening coeff 1
of async motor 1
0.0
~
100.0
87%
×
F08.14
Field weakening coeff 2
of async motor 1
0.0
~
100.0
75%
×
F08.15
Field weakening coeff 3
of async motor 1
0.0
~
100.0
70%
×