- 12 -
F08.30
Autotuning of motor 1
0: No autotuning
0
×
1: Static autotuning of
async motor
2: Rotary autotuning of
async motor
Group F09 V/f Control Parameters of Motor 1
F09.00
V/f curve setting
0
:
Linear V/f
3
×
1
:
Multi-stage V/f
2
:
1.2
次方
V/F
3
:
1.4
次方
V/F
4
:
1.6
次方
V/F
5
:
1.8
次方
V/F
6
:
2.0
次方
V/F
7:V/F complete separation
8: V/F half separation
F09.01
Torque boost
0.0
~
30.0%
0.0%
:
(fixed torque boost)
Model
defined
△
F09.02
Cut-off frequency of torque
boost
0.00
~最大频率
50.00Hz
△
F09.03
Multi-point V/F frequency
1(F1)
0.00
~
F09.05
0.00Hz
△
F09.04
Multi-point V/F voltage 1
(V1)
0.0
~
100.0
0.0%
△
F09.05
Multi-point V/F frequency
2(F2)
F09.03
~
F09.05
0.00Hz
△
F09.06
Multi-point V/F voltage 2
(V2)
0.0
~
100.0
0.0%
△
F09.07
Multi-point V/F frequency
3(F3)
F09.05
~
F09.09
0.00Hz
△
F09.08
Multi-point V/F voltage 3
(V3)
0.0
~
100.0
0.0%
△
F09.09
Multi-point V/F frequency
4(F4)
F09.07
~
rated
motor
frequency
50.00Hz
△
F09.10
Multi-point V/F voltage 4
(V4)
0.0
~
100.0
Ue=100.0%
100.0%
△
F09.11
V/F slip compensation gain
0.0
~
300.0%
0.0%
△
F09.12
Stator voltagedrop
compensation gain
0.0
~
200.0%
100.0%
△
F09.13
Excitation boost gain
0.0
~
200.0%
100.0%
△
F09.14
Oscillation Suppression
0.0
~
300.0%
0.0%
△
Group F11 Protection Parameters
F11.00
Current limit control
0: Current limit disabled
1
×
1: Current limit mode 1
2: Current limit mode 2
F11.01
Current limit
100.0
~
200.0%
150.0%
×
F11.02
Frequency decreasing
time(limit current in constant
speed operation)
0.0
~
6000.0s (Valid in
mode 1)
5.0s
△
F11.03
Current limit mode 2
proportion gain
0.1
~
100.0%
3.0%
△
F11.04
Current limit mode 2 integral
time
0.000
~
1.000s
0.010s
△
F11.05
Overvoltage Stall Control
0:Overvoltage
stall
disabled
1
×
1:Overvoltage stall mode