FR100L&FR200L For Wire drawing machine
- 15 -
Group U00 Status Monitoring
U00.00
Running frequency
0.00
~
Fup
0.00Hz
⊙
U00.01
Set frequency
0.00
~
Fmax
0.00Hz
⊙
U00.02
Output voltage
0
~
660V
0.0V
⊙
U00.03
Output current
0.0
~
3000.0A
0.0A
⊙
U00.04
Output power
-3000.0
~
3000.0kW
0.0kW
⊙
U00.05
Estimated Motor
Speed
0
~
60000rpm
0rpm
⊙
U00.06
Bus voltage
0
~
1200V
0V
⊙
U00.07
Synchronous Frequency
0.00
~
Fup
0.00Hz
⊙
U00.08
PLC step
1
~
15
1
⊙
U00.09
Program Operation Time
0.0
~
6000.0s(h)
0.0s(h)
⊙
U00.10
PID set
0
~
60000
0
⊙
U00.11
PID feedback
0
~
60000
0
⊙
U00.12
Status of DI1
~
DI5 digital
input terminal
DI5 DI4 DI3 DI2 DI1
00000
⊙
U00.13
Status of DI6
~
DI7 digital
input terminal
DI7 DI6
00
⊙
U00.14
Status of digital output
terminal
R2 R1 Y2 Y1
0000
⊙
U00.15
AI1 input
0.0
~
100.0%
0.0%
⊙
U00.16
AI2 input
0.0
~
100.0%
0.0%
⊙
U00.17
AI3 input
-100.0
~
100.0%
0.0%
⊙
U00.18
Keypad potentiometer input
0.0
~
100.0%
0.0%
⊙
U00.19
HI input
0.00
~
100.00kHz
0.00kHz
⊙
U00.20
AO1 output
0.0
~
100.0%
0.0%
⊙
U00.21
AO2 output
0.0
~
100.0%
0.0%
⊙
U00.22
HO output
0.00
~
100.00kHz
0.00kHz
⊙
U00.23
Temperature of inverter
-40.0
℃~
120.0
℃
0.0
℃
⊙
U00.24
Accumulative power-on time
0
~
65535min
0min
⊙
U00.25
Accumulative running time
0
~
6553.5min
0.0min
⊙
U00.26
Cumulative power-on
time
0
~
65535h
0h
⊙
U00.27
Cumulative running time
0
~
65535h
0h
⊙
U00.28
Count value
0
~
65535
0
⊙
U00.29
Length value
0
~
65535m
0m
⊙
U00.30
Linear speed
0
~
65535m/min
0m/Min
U00.31
Output torque
0.0
~
300.0%
0.0%
⊙
Group U01 Fault Record
U01.00
Fault type
0: No fault
0
⊙
Err01
:
Accel overcurrent
Err02
:
Decel overcurrent
Err03
:
Constant-speed
overcurrent
Err04
:
Accel overvoltage
Err05
:
Decel overvoltage
Err06
:
Constant-speed
overvoltage
Err07
:
Bus undervoltage
Err08
:
Short circuit
Err09
:
Power input phase loss