FR100L&FR200L For Wire drawing machine
- 27 -
Chapter 5 Parameter setting reference
5.1 Parameter setting reference of drive for water tank type wire drawing machine host
Function code
Parameter Name
Recommended setting value
F01.01
Master Frequency
Command Source
2
:
AI1
F01.08
Maximum frequency
(
Fmax)
75.00Hz
F01.09
Upper limit frequency (Fup)
55.00Hz
F02.00
Run command
1: Terminal control (LED on)
F02.02
Reverse-proof action
0: Reverse enabled
F02.12
Stop mode
0: Ramp to stop
F03.00
Accel time 1
40.0s
F03.01
Decel time 1
40.0s
F03.08
Jog accel time
8.0s
F03.09
Jog decel time
8.0s
F04.00
Function of terminal DI1
1
:
Running forward (FWD)
(
FWD
)
F04.01
Function of terminal DI2
4
:
JOG forward
(
FJOG
)
F04.02
Function of terminal DI3
7
:
Fault reset
F04.03
Function of terminal DI4
5
:
JOG reverse
(
RJOG
)
F04.04
Function of terminal DI5
39
:
External wire break fault
F05.00
Y1 output function
2
:
Fault output
H00.00
Type of wire drawing machine
0
:
Host
Note: Refer to group HOO for other parameters
5.2 Parameter setting reference of drive for water tank type wire drawing machine winding
Function code
Parameter Name
Recommended setting value
F01.08
Maximum frequency
(
Fmax)
75.00Hz
F01.09
Upper limit frequency (Fup)
75.00Hz
F02.00
Run command
1: Terminal control (LED on)
F02.02
Reverse-proof action
1:Reverse disabled
F02.12
Stop mode
0
:
Ramp to stop
F02.14
Stop DC braking current
10.0%
(
Base on real condition
)
F02.16
Stop DC braking time
1.5
(
Base on real condition
)
F03.00
Accel time 1
2.0s
F03.01
Decel time 1
2.0s
F03.08
Jog accel time
2.0s
F03.09
Jog decel time
2.0s
F04.00
Function of terminal DI1
1
:
Running forward (FWD)
F04.01
Function of terminal DI2
4
:
JOG forward
F04.02
Function of terminal DI3
7
:
Fault reset (RESET)
F04.03
Function of terminal DI4
5
:
JOG reverse
F04.04
Function of terminal DI5
39
:
External wire break fault
F04.15
FWD/REV terminal
control mode
2
:
Three-wire mode 1
F05.00
Y1 output function
3
:
Frequency-level detection
FDT1 output
F05.10
FDT1 upper bound
1.00Hz
F05.11
FDT1 lower bound
2.00Hz
H00.00
Type of wire drawing machine
1
:
Winding
Note: Refer to group HOO for other parameters