5.3 Parameter setting reference of drive for straight line wire drawing machine
Function code
Parameter Name
Recommended setting value
F01.08
Maximum frequency
(
Fmax)
75.00Hz
F01.09
Upper limit frequency (Fup)
75.00Hz
F02.00
Run command
1: Terminal control (LED on)
F02.02
Reverse-proof action
1
:
Reverse disabled
F02.12
Stop mode
0: Ramp to stop
F03.00
Accel time 1
20.0s
F03.01
Decel time 1
20.0s
F03.08
Jog accel time
20.0s
F03.09
Jog decel time
20.0s
F04.00
Function of terminal DI1
1
:
Running forward (FWD)
F04.01
Function of terminal DI2
4
:
JOG forward
F04.02
Function of terminal DI3
7
:
Fault reset (RESET)
F04.03
Function of terminal DI4
5
:
JOG reverse
F04.04
Function of terminal DI5
5
:
JOG reverse
H00.00
Type of wire drawing machine
3
:
straight line wire drawing
machine
Note: Refer to group HOO for other parameters
5.4 Parameter setting reference of drive for unwinding
Function code
Parameter Name
Recommended setting value
F01.08
Maximum frequency
(
Fmax)
75.00Hz
F01.09
Upper limit frequency (Fup)
75.00Hz
F02.00
Run command
1: Terminal control (LED on)
F02.02
Reverse-proof action
0
:
Reverse enabled
F02.12
Stop mode
0: Ramp to stop
F02.14
Stop DC braking current
10.0%
(
Base on real condition
)
F02.16
Stop DC braking time
1.5
(
Base on real condition
)
F03.00
Accel time 1
2.0s
F03.01
Decel time 1
2.0s
F03.08
Jog accel time
2.0s
F03.09
Jog decel time
2.0s
F04.00
Function of terminal DI1
1
:
Running forward (FWD)
F04.01
Function of terminal DI2
4
:
JOG forward
F04.02
Function of terminal DI3
7
:
Fault reset (RESET)
F04.03
Function of terminal DI4
5
:
JOG reverse
F04.04
Function of terminal DI5
39
:
External wire break fault
H00.00
Type of wire drawing machine
2
:
Unwinding
Note: Refer to group HOO for other parameters