Goodrive20 Series VFD
Function parameter list
-51-
Function
code
Name
Description
Default Modify
P03.20
Electromoti
ve torque
upper limit
set through
keypad
The function codes are used to set the
torque limits.
Setting range: 0.0
–300.0% (of the rated
motor current)
180.0%
○
P03.21
Braking
torque
upper limit
set through
keypad
180.0%
○
P03.22
Weakening
coefficient
in constant
power zone
Used when the AM is in flux-weakening
control.
The function codes
P03.22
and
P03.23
are
valid at constant power. The motor enters
the flux-weakening state when the motor
runs above the rated speed. Change the
flux-weakening curve by modifying the
flux-weakening control coefficient. The larger
the coefficient, the steeper the curve, the
smaller the coefficient, the smoother the
curve.
T
f
0.1
Flux-weakening
coefficient of motor
1.0
2.0
Min. flux-weakening limit of motor
Setting range of
P03.22
: 0.1
–2.0
Setting range of
P03.23
: 10%
–100%
0.3
○
P03.23
Lowest
weakening
point in
constant
power zone
20%
○
P03.24
Max.
voltage limit
P03.24
set the max. output voltage of the
VFD. Set the value according to onsite
conditions
Setting range: 0.0
–120.0%
100.0%
◎
P03.25
Pre-exciting
time
Pre-exciting is performed for the motor when
the VFD starts up. A magnetic field is built up
0.300s
○