Goodrive20 Series VFD
Optional peripheral accessories
-160-
C.6.2 C3 filter
Goodrive20 series 1PH 220V/3PH 380V 2.2kW and lower VFD models, 3PH 220V 0.75kW
and lower VFD models can satisfy the requirements of IEC 61800-3 C3 as shown in the table
as follows. 3PH 380V 4kW and higher VFD models, 3PH 220V 1.5kW and higher VFD models
can be set to satisfy the requirements of IEC 61800-3 C3 or not by jumper J10.
(Note:
Jumper
J10 is put in the same bag with operation manual
)
Note:
Disconnect J10 when either of following situations occurs:
1. EMC filter is suitable for the neutral-grounding grid system. If it is used in IT grid system
(neutral point is not grounded), disconnect J10;
2. During configuring residual current circuit-breaker, if tripping occurred during startup,
disconnect J10.
Interference filters on the input side can reduce the interference of VFDs (when used) on the
surrounding devices.
Noise filters on the output side can decrease the radio noise caused by the cables between
VFDs and motors and the leakage current of conducting wires.
We provide some of the filters for you to choose.
Model
Input filter
GD20-0R4G-S2
FLT-PS2004L-C-G
GD20-0R7G-S2
GD20-1R5G-S2
GD20-2R2G-S2
GD20-0R4G-2
FLT-P04008L-C-G
GD20-0R7G-2
GD20-0R7G-4
GD20-1R5G-4
GD20-2R2G-4