Goodrive20 Series VFD
Keypad operation
-25-
Serial
No.
Name
Description
DATA
ENT
Entry key
Enter the menu step-by-step
Confirm parameters
UP key
Increase data or function code progressively
DOWN key
Decrease data or function code progressively
SHIFT
Right-shift key
Move right to select the displaying parameter
circularly in stopping and running mode.
Select the parameter modifying digit during
the parameter modification
RUN
Run key
This key is used to operate on the VFD in key
operation mode
STOP
RST
Stop/
Reset key
This key is used to stop in running state and it
is limited by function code P07.04
This key is used to reset all control modes in
the fault alarm state
QUICK
JOG
Quick key
The function of this key is confirmed by
function code
P07.02
.
5
Analog
potenti
ometer
AI1, When the external common keypad (without the function of
parameter copy) is valid, the difference between the local keypad AI1
and the external keypad AI1 is:
When the external keypad AI1 is set to the Min. value, the local keypad
AI1 will be valid and P17.19 will be the voltage of the local keypad AI1;
otherwise, the external keypad AI1 will be valid and P17.19 will be the
voltage of the external keypad AI1.
Note
: If the external keypad AI1 is frequency reference source, adjust
the local potentiometer AI1 to 0V/0mA before starting the VFD.
6
Keypad
port
External keypad port. When the external keypad with the function of
parameter copying is valid, the local keypad LED is off. When the
external keypad without the function of parameter copying is valid, the
local and external keypad LEDs are on.
Note:
Only the external keypad which has the function of parameters
copy owns the function of parameters copy, other keypads do not have.
(only for the VFDs
≤2.2kW)